Laserfiche WebLink
(2) An electrically operated switch or circuit-breaker <br />provided the switch or circuit-breaker can be opened by ,hand in event <br />of a failure of the power supply and the open and closed positions are <br />clearly indicated to the operator. <br /> <br /> (e) Externally Operable. ~_n enclosed service switch or cir- <br />cuit breaker shall be exterr~tly operable. See definition Article 100. <br /> <br /> It is recm~ended that where the current of a single cir- <br />cuit, or group of circuits, is seperately metered, as in apartment <br />house installations, devices be installed in a convenient location to <br />control each separately metered installation, such devices being en- <br />closed and the switch or circuit breaker being externally operable. <br /> <br /> (f) Indicating. The disconnecti~ means shall plainly in- <br />dicate whetlner it is in the open or closed position. <br /> <br /> (g) Switch and Circuit Breaker. It may consist of not more <br />than six switches or six circuit bres_kers i~ a cmwaon enclosure, or in <br />a group of separate enclosures. Two or three single pole switches or <br />breakers, capable of individual operation, may be installed on multi- <br />wire circuits, one pole for each urgrouunded conductor, as one multipole <br />disconnect [where applicable, see Sec'tion 230-70 (h)] provided they are <br />~quipped with "b~ndle ties," "handles vritbin 1/16 ~ch proximity," a <br />"master handle," or "other means," ,.making it practical to disconnect <br />all conductors of the service with no more than six operations of the <br />hmnd. <br /> <br />See Section200-5 and Section 384-16(a). <br /> <br /> (h) Simultaneous Openings. ~ne disconnecting means shall simul- <br />taneously disconnect all ungrour~ed conductors, except for 3-wire direct- <br />current or sit, lc-phase cimcuits or multiwire circuits that do not <br />supply polyphase motors. <br /> <br />See Section 200-5(a). <br /> <br /> (i) Disconnection of Grounded Conductor. V~ere the switch or <br />circuit breaker does not interrupt.the ~rounded conducvor, other means <br />shall be proa~ded in the service cabinet or on the switchboard fordis- <br />connecting ~ne grounded con,actor frcm the interior wiring. <br /> <br />2. Pm amergency exists and ~nis ordinance shall become effective on <br />Janua~y 1, 1967. <br /> <br /> Adopted by the Council of the City of Portamouth, Virgir_ia, <br />at a meeting held December 13, 1966. <br /> <br />Teste: <br /> <br />City Clerk <br /> <br /> <br />