My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1978 Ordinances
Portsmouth-City-Attorney
>
ORDINANCES
>
1978
>
1978 Ordinances
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2001 6:41:24 PM
Creation date
6/26/2001 5:14:15 PM
Metadata
Fields
Template:
Ord/Resolutions
Year
1978
Ord/Resolutions - Type
Ordinances
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
218
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Where investigation discloses that unusual or extraordi- <br /> nary hazards require more stringent means of protection, the <br /> director shall have the authority to require the installation <br /> of the same. The director shall in all cases specify the facts <br /> constituting the greater hazard found to require more stringent <br /> protective measures. The more stringent protective measures <br /> shall be related to such unusual or extraordinary hazards and <br /> shall be no more burdensome than is reasonably necessary %o al- <br /> leviate or guard against such hazards'. The director shall specify <br /> in writing to the owner the manner in which the more stringent <br /> protective measures alleviate or guard against the unusual or ex- <br />-~-~traordinary hazards. <br /> <br />Section 38-67.5. Connections to boilers. <br /> <br /> Potable water connections to boilers shall be made through <br />an air gap or provided with an approved backflow preventer. <br /> <br />Section 38-67.6. Connections to refrigerating units, etc. <br /> <br /> Potable water inlet connections to refrigerating unit con- <br />densers, cooling jacke~s and air conditioning cooling systems <br />will be air gapped or provided with an approved backflow pre- <br />~ente~. <br /> <br />Section 38-67.7. Fire service systems. <br /> <br /> ('a) Fire service systems having direct connections from <br />· waterworks with no pumps or storage facilities, no connections <br />to other water supplier, no antifreeze or other chemicals added <br />to the fire system, and all sprinkler heads discharging to the <br />atmosphere are not required to have positive pro~ective devices. <br /> <br /> (b) In systems such as these listed in subsection (a) of <br />this 'section which have booster pumps installed in the connection <br />from.the waterworks provision shall be made to avoid lowering the <br />pressure at the connection to the waterworks below ten psi. <br /> <br /> lc) Systems with direct connections to the waterworks, which <br />-are comparable to the systems described under subsections (a) and <br /> (b) of this section and which have an auxiliary supply wikhin one <br /> thousand ~eve~ hundred feet of the pumper connection, must pro- <br /> vide a~ a~r'gap, a reduced pressure principle backflow preventer <br /> or a double gate-double check valve assembly, depending on the <br /> ~uality of ~he auxiliary supply. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.